Medical Device

Compliance-Traceable Resolution Agent

Checks technician resolution notes against service-record requirements and flags missing details before the case closes, so Quality isn't chasing the technician for it weeks later.

Overview

A resolution note that passes cursory review can still fail a compliance audit. The Compliance-Traceable Resolution Agent checks the resolution against service-documentation requirements, independent of whether the underlying event turns out to be reportable. It validates the Pathways reference, reviews key evidence areas including as-found condition, root cause statement, and post-repair verification, and flags specific gaps so the technician can complete the record on the spot, while they still have the unit and the memory of the visit. Service closes the right cases. Quality gets records that hold up.

Capabilities

Check resolution notes against service-record standards before case closure

Reviews the record against required documentation standards before the case is submitted, not after Quality flags it weeks later.

Validate that the Pathways reference covers the actual visit

Confirms the referenced Pathways record covers the service visit, not just that a ticket number was entered.

Review the four evidence areas Quality rejects records over

As-found condition, root cause statement, corrective action, and return-to-service verification are each reviewed independently.

Flag specific gaps before the technician submits

Missing details are identified precisely so the technician can complete the record on site, while they still have the unit and the context of the visit.

Example use case

User input

SR-2026-100442 resolution notes submitted for compliance review. Strainer fouling on MD987.

Agent summary

Input identified
SR-2026-100442. MD987. Resolution notes received.
Context captured
Pathways reference validated. Four evidence areas reviewed.
Evidence surfaced
  • As-found condition: present — fouled inlet strainer, pressure regulator out of adjustment
  • Root cause: confirmed — strainer fouling
  • Corrective action: present — strainer cleaned, regulator replaced (P/N 60427, lot L3318-02)
  • Post-repair verification: present — vacuum leak test and full cycle, all in spec

Flagged by agent

Resolution record complete. Recurrence pattern noted: third call on this unit. Same fouling pattern on two other MD987s at site.

Agent handoff

Record ready for Quality handoff:

  • All four required fields confirmed complete
  • Pathways reference validated against visit scope
  • Recurrence note included for Quality awareness

Agent workflow 

1. Technician enters resolution notes

Post-Work Documentation structures the notes into a record before close-out, including the Pathways reference.

2. Record checked against service-record requirements

As-found condition, root cause, parts traceability, and return-to-service testing are each reviewed.

3. Pathways reference validated

The agent confirms the referenced Pathways record covers the service visit, not just that a ticket number was entered.

4. Intake narrative reconciled against the resolution record

What the customer reported is checked against what the technician found and fixed.

5. Gaps flagged before the case closes

The technician completes missing details on site, with the unit still available and the visit still in memory.